IEC 60079-10-2:2015 RLV
Norm
Explosive atmospheres - Part 10-2: Classification of areas - Explosive dust atmospheres
- Zurückgezogen
Alle Preise inkl. MwSt.
Bleiben Sie mit der IEC-Watchlist immer auf dem neuesten Stand
Mit der IEC-Watchlist haben Sie die Möglichkeit, die für Sie relevanten Normnummern oder technische Fachgebiete in Ihre persönliche Watchlist aufzunehmen. Bei Erscheinen einer neuen IEC-Norm erhalten Sie automatisch eine E-Mail.
Um eine Norm der IEC-Watchlist hinzufügen zu können, müssen Sie sich zuerst einloggen.
Zuständiges Komitee:
Hauptnummer/Reihe:
60079
IEC 60079-10-2:2015 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
IEC 60079-10-2:2015 is concerned with the identification and classification of areas where explosive dust atmospheres and combustible dust layers are present, in order to permit the proper assessment of ignition sources in such areas. In this standard, explosive dust atmospheres and combustible dust layers are treated separately. In Clause 4, area classification for explosive dusts clouds is described, with dust layers acting as one of the possible sources of release. In Clause 7 other general considerations for dust layers are described. The examples in this standard are based on a system of effective housekeeping being implemented in the plant to prevent dust layers from accumulating. Where effective housekeeping is not present, the area classification includes the possible formation of explosive dust clouds from dust layers. The principles of this standard can also be followed when combustible fibres or flyings might cause a hazard. This standard is intended to be applied where there can be a risk due to the presence of explosive dust atmospheres or combustible dust layers under normal atmospheric conditions. Please refer to the foreword of the document for a detailed listing of the significant technical changes from the previous edition.
Keywords: explosive dust atmospheres, combustible dust layers, ignition hazard
IEC 60079-10-2:2015 is concerned with the identification and classification of areas where explosive dust atmospheres and combustible dust layers are present, in order to permit the proper assessment of ignition sources in such areas. In this standard, explosive dust atmospheres and combustible dust layers are treated separately. In Clause 4, area classification for explosive dusts clouds is described, with dust layers acting as one of the possible sources of release. In Clause 7 other general considerations for dust layers are described. The examples in this standard are based on a system of effective housekeeping being implemented in the plant to prevent dust layers from accumulating. Where effective housekeeping is not present, the area classification includes the possible formation of explosive dust clouds from dust layers. The principles of this standard can also be followed when combustible fibres or flyings might cause a hazard. This standard is intended to be applied where there can be a risk due to the presence of explosive dust atmospheres or combustible dust layers under normal atmospheric conditions. Please refer to the foreword of the document for a detailed listing of the significant technical changes from the previous edition.
Keywords: explosive dust atmospheres, combustible dust layers, ignition hazard
Dieses Dokument wird folgenden, in Fettschrift gekennzeichneten, Fachgebiet(en) zugeordnet:
- 29Elektrotechnik
- 29.020Elektrotechnik im Allgemeinen
- 29.030Magnetische Werkstoffe
- 29.035Isolierstoffe
- 29.040Isolierende Fluide
- 29.045Halbleitende Stoffe
- 29.050Leitende Stoffe. Supraleitung
- 29.060Drähte. Kabel. Leitungen
- 29.080Isolierung
- 29.100Bauteile für elektrische Geräte
- 29.120Elektrisches Zubehör
- 29.130Schaltgeräte
- 29.140Lampen. Lampenzubehör
- 29.160Drehende elektrische Maschinen
- 29.180Transformatoren. Drosselspulen
- 29.200Gleichrichter. Stromrichter. Stabilisierte Stromversorgung
- 29.220Galvanische Zellen. Batterien
- 29.240Stromnetz
- 29.260Elektrische Betriebsmittel für den Einsatz unter besonderen Bedingungen
- 29.280Ortsfeste elektrische Bahnanlagen. Fahrstromversorgung
Artikeldetails
- Edition: 2.0
- Umfang: 92 Seiten
- Sprache: Englisch
- Ausgabedatum: 2015-01
- Erscheinungsdatum: 2015-01-16
- Zurückziehungsdatum: 2026-06-29