IEC 60793-1-41:2024 RLV
Norm
Optical fibres - Part 1-41: Measurement methods and test procedures - Bandwidth
- Gültig
Alle Preise inkl. MwSt.
Bleiben Sie mit der IEC-Watchlist immer auf dem neuesten Stand
Mit der IEC-Watchlist haben Sie die Möglichkeit, die für Sie relevanten Normnummern oder technische Fachgebiete in Ihre persönliche Watchlist aufzunehmen. Bei Erscheinen einer neuen IEC-Norm erhalten Sie automatisch eine E-Mail.
Um eine Norm der IEC-Watchlist hinzufügen zu können, müssen Sie sich zuerst einloggen.
Zuständiges Komitee:
Hauptnummer/Reihe:
60793
IEC 60793-1-41:2024 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
IEC 60793-1-41:2024 describes three methods for determining and measuring the modal bandwidth of multimode optical fibres (see IEC 60793-2-10, IEC 60793-2-30, and the IEC 60793-2-40 series). The baseband frequency response is directly measured in the frequency domain by determining the fibre response to a sinusoidaly modulated light source. The baseband response can also be measured by observing the broadening of a narrow pulse of light. The calculated response is determined using differential mode delay (DMD) data. The three methods are:
Method A – Time domain (pulse distortion) measurement
Method B – Frequency-domain measurement
Method C – Overfilled launch modal bandwidth calculated from differential mode delay (OMBc)
Method A and method B can be performed using one of two launches: an overfilled launch (OFL) condition or a restricted mode launch (RML) condition. Method C is only defined for A1-OM3 to A1-OM5 multimode fibres and uses a weighted summation of DMD launch responses with the weights corresponding to an overfilled launch condition. The relevant test method and launch condition is chosen according to the type of fibre.
NOTE 1 These test methods are commonly used in production and research facilities and are not easily accomplished in the field.
NOTE 2 OFL has been used for the modal bandwidth value for LED-based applications for many years. However, no single launch condition is representative of the laser (e.g. VCSEL) sources that are used for gigabit and higher rate transmission. This fact drove the development of IEC 60793-1-49 for determining the effective modal bandwidth of laser optimized 50 µm fibres. See IEC 60793-2-10 and IEC 61280-4-1 for more information.
This fourth edition cancels and replaces the third edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) the addition of a direct reference for method A and method B.
IEC 60793-1-41:2024 describes three methods for determining and measuring the modal bandwidth of multimode optical fibres (see IEC 60793-2-10, IEC 60793-2-30, and the IEC 60793-2-40 series). The baseband frequency response is directly measured in the frequency domain by determining the fibre response to a sinusoidaly modulated light source. The baseband response can also be measured by observing the broadening of a narrow pulse of light. The calculated response is determined using differential mode delay (DMD) data. The three methods are:
Method A – Time domain (pulse distortion) measurement
Method B – Frequency-domain measurement
Method C – Overfilled launch modal bandwidth calculated from differential mode delay (OMBc)
Method A and method B can be performed using one of two launches: an overfilled launch (OFL) condition or a restricted mode launch (RML) condition. Method C is only defined for A1-OM3 to A1-OM5 multimode fibres and uses a weighted summation of DMD launch responses with the weights corresponding to an overfilled launch condition. The relevant test method and launch condition is chosen according to the type of fibre.
NOTE 1 These test methods are commonly used in production and research facilities and are not easily accomplished in the field.
NOTE 2 OFL has been used for the modal bandwidth value for LED-based applications for many years. However, no single launch condition is representative of the laser (e.g. VCSEL) sources that are used for gigabit and higher rate transmission. This fact drove the development of IEC 60793-1-49 for determining the effective modal bandwidth of laser optimized 50 µm fibres. See IEC 60793-2-10 and IEC 61280-4-1 for more information.
This fourth edition cancels and replaces the third edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) the addition of a direct reference for method A and method B.
Dieses Dokument wird folgenden, in Fettschrift gekennzeichneten, Fachgebiet(en) zugeordnet:
- 33Telekommunikation. Audiotechnik. Videotechnik
- 33.020Telekommunikation im Allgemeinen
- 33.030Telekommunikationsdienste. Telekommunikationsanwendungen
- 33.040Telekommunikationssysteme
- 33.050Telekommunikationsendgeräte
- 33.060Funktechnik
- 33.070Mobilfunk
- 33.080Diensteintegriertes Digitalnetz (ISDN)
- 33.100Elektromagnetische Verträglichkeit (EMV)
- 33.120Bauteile und Zubehör für Telekommunikationsgeräte
- 33.140Besondere Messinstrumente für Telekommunikation
- 33.160Audiotechnik. Videotechnik. Audiovisuelle Technik
- 33.170Rundfunktechnik (Radio. Fernsehen)
- 33.180Lichtwellenleitersysteme (LWL)
- 33.200Fernüberwachung. Fernsteuerung
Artikeldetails
- Edition: 4.0
- Umfang: 92 Seiten
- Sprache: Englisch
- Ausgabedatum: 2024-04
- Erscheinungsdatum: 2024-04-19
Item 1 of 9
Item 1 of 6