IEC 60794-1-111: 2023 defines the test procedure to determine the ability of an optical fibre cable to withstand bending around a test mandrel. The primary purpose of this procedure is to measure the change in attenuation when the cable is bent around a test mandrel. A secondary purpose is to assess whether the cable has been physically damaged by bending. NOTE 1 This test can be utilized at any specified temperature, including the low or high temperature limits for the cable. NOTE 2 The bend test procedure for cable elements is specified in IEC 60794-1-301, method G1. This document partially cancels and replaces IEC 60794-1-21:2015. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to IEC 60794-1-21:2015:
a) the nominal sample length was newly specified as 10 m between the cable element fixing points at both ends, unless otherwise specified;
b) the number of turns on the mandrel in Figure 1 for the single-helix configuration were corrected to match the number of turns shown in the figure for the two-helix configuration;
c) requirements on the turnaround loop were added for method E11A, two-helix configuration;
d) the turnaround loop with the same diameter as the mandrel was taken into account for calculation of the number of turns of each helix for method E11A, two-helix configuration;
e) added a formula for calculation of the number of revolutions in each helix for method E11A, two-helix configuration;
f) added a description for the procedure when the turnaround loop diameter is larger than the mandrel diameter for method E11A, two-helix configuration;
g) all the figures were updated and the different components labelled;
h) added the attenuation monitoring equipment in 4.2 for the apparatus and the description to measure the change in attenuation in the test methods E11A and E11B;
i) added Clause 9 for details to be reported;
j) added Annex A showing an example of a special mandrel to perform the bend test according to method E11A, two-helix configuration;
k) added Annex B providing the rationale for the options of method E11A, two-helix configuration.
a) the nominal sample length was newly specified as 10 m between the cable element fixing points at both ends, unless otherwise specified;
b) the number of turns on the mandrel in Figure 1 for the single-helix configuration were corrected to match the number of turns shown in the figure for the two-helix configuration;
c) requirements on the turnaround loop were added for method E11A, two-helix configuration;
d) the turnaround loop with the same diameter as the mandrel was taken into account for calculation of the number of turns of each helix for method E11A, two-helix configuration;
e) added a formula for calculation of the number of revolutions in each helix for method E11A, two-helix configuration;
f) added a description for the procedure when the turnaround loop diameter is larger than the mandrel diameter for method E11A, two-helix configuration;
g) all the figures were updated and the different components labelled;
h) added the attenuation monitoring equipment in 4.2 for the apparatus and the description to measure the change in attenuation in the test methods E11A and E11B;
i) added Clause 9 for details to be reported;
j) added Annex A showing an example of a special mandrel to perform the bend test according to method E11A, two-helix configuration;
k) added Annex B providing the rationale for the options of method E11A, two-helix configuration.
Dieses Dokument wird folgenden, in Fettschrift gekennzeichneten, Fachgebiet(en) zugeordnet:
- 33Telekommunikation. Audiotechnik. Videotechnik
- 33.020Telekommunikation im Allgemeinen
- 33.030Telekommunikationsdienste. Telekommunikationsanwendungen
- 33.040Telekommunikationssysteme
- 33.050Telekommunikationsendgeräte
- 33.060Funktechnik
- 33.070Mobilfunk
- 33.080Diensteintegriertes Digitalnetz (ISDN)
- 33.100Elektromagnetische Verträglichkeit (EMV)
- 33.120Bauteile und Zubehör für Telekommunikationsgeräte
- 33.140Besondere Messinstrumente für Telekommunikation
- 33.160Audiotechnik. Videotechnik. Audiovisuelle Technik
- 33.170Rundfunktechnik (Radio. Fernsehen)
- 33.180Lichtwellenleitersysteme (LWL)
- 33.200Fernüberwachung. Fernsteuerung
Artikeldetails
- Edition: 1.0
- Umfang: 37 Seiten
- Sprache: Bilingual (EN/FR)
- Ausgabedatum: 2023-09
- Erscheinungsdatum: 2023-09-19
Item 1 of 9