IEC TR 62926:2019
Norm
Medical electrical system - Guidelines for safe integration and operation of adaptive external-beam radiotherapy systems for real-time adaptive radiotherapy
- Gültig
Alle Preise inkl. MwSt.
Bleiben Sie mit der IEC-Watchlist immer auf dem neuesten Stand
Mit der IEC-Watchlist haben Sie die Möglichkeit, die für Sie relevanten Normnummern oder technische Fachgebiete in Ihre persönliche Watchlist aufzunehmen. Bei Erscheinen einer neuen IEC-Norm erhalten Sie automatisch eine E-Mail.
Um eine Norm der IEC-Watchlist hinzufügen zu können, müssen Sie sich zuerst einloggen.
Zuständiges Komitee:
Hauptnummer/Reihe:
62926
IEC TR 62926:2019 provides guidelines for safe integration and operation of an adaptive external-beam RADIOTHERAPY system (AEBRS) for intra-fractionally moving rigid TARGET VOLUMEs, where required equipment can be sourced from one or several MANUFACTURERs. In particular it addresses guidelines to help ensure safe integration and operation for the PATIENT, OPERATOR, other persons and sensitive devices in the vicinity. In this document, the word “system” is hereafter used to refer to an AEBRS.
This document specifies the safety guidelines for a MANUFACTURER or RESPONSIBLE ORGANIZATION who integrates the AEBRS for intra-fractionally moving rigid TARGET VOLUMEs. If a RESPONSIBLE ORGANIZATION integrates an AEBRS, then it takes the role of MANUFACTURER and will be referred to as a MANUFACTURER throughout this document.
This document includes reference models of the AEBRS for intra-fractionally moving rigid TARGET VOLUMEs and HAZARDs which, at a minimum, are considered during the RISK ANALYSIS.
Although TARGET VOLUMES and OARs can deform during motion, adaptations in response to deformations of the TARGET VOLUME are out of the scope of this document. The scope is limited to rigid TARGET VOLUMEs exhibiting intra-fractional movements, both translational and rotational. While technical HAZARDs are discussed in this document, the RESPONSIBLE ORGANIZATION is reminded that clinical judgement is always employed when determining clinical usability and reviewing TREATMENT PARAMETER changes.
This document does not specifically address HAZARD mitigations for each of the HAZARDs mentioned in the document; however, some mitigations are given as examples in Clauses 4 and 5. All guidelines in this document are intended to be implemented in accordance with the general standard IEC 60601-1:2005 and IEC 60601-1:2005/AMD1:2012, with special attention to 4.2 of IEC 60601-1:2005 and IEC 60601-1:2005/AMD1:2012.
This document specifies the safety guidelines for a MANUFACTURER or RESPONSIBLE ORGANIZATION who integrates the AEBRS for intra-fractionally moving rigid TARGET VOLUMEs. If a RESPONSIBLE ORGANIZATION integrates an AEBRS, then it takes the role of MANUFACTURER and will be referred to as a MANUFACTURER throughout this document.
This document includes reference models of the AEBRS for intra-fractionally moving rigid TARGET VOLUMEs and HAZARDs which, at a minimum, are considered during the RISK ANALYSIS.
Although TARGET VOLUMES and OARs can deform during motion, adaptations in response to deformations of the TARGET VOLUME are out of the scope of this document. The scope is limited to rigid TARGET VOLUMEs exhibiting intra-fractional movements, both translational and rotational. While technical HAZARDs are discussed in this document, the RESPONSIBLE ORGANIZATION is reminded that clinical judgement is always employed when determining clinical usability and reviewing TREATMENT PARAMETER changes.
This document does not specifically address HAZARD mitigations for each of the HAZARDs mentioned in the document; however, some mitigations are given as examples in Clauses 4 and 5. All guidelines in this document are intended to be implemented in accordance with the general standard IEC 60601-1:2005 and IEC 60601-1:2005/AMD1:2012, with special attention to 4.2 of IEC 60601-1:2005 and IEC 60601-1:2005/AMD1:2012.
Dieses Dokument wird folgenden, in Fettschrift gekennzeichneten, Fachgebiet(en) zugeordnet:
- 11Medizintechnik
- 11.020Medizinische Wissenschaften im Allgemeinen. Gesundheitswesen im Allgemeinen
- 11.040Medizinische Geräte
- 11.060Zahnmedizin
- 11.080Sterilisation. Desinfektion
- 11.100Labormedizin
- 11.120Pharmazie
- 11.140Krankenhausausstattung
- 11.160Erstversorgung (Erste Hilfe)
- 11.180Hilfsmittel für Behinderte
- 11.200Geburtenkontrolle. Mechanische Verhütungsmittel
- 11.220Veterinärmedizin
Artikeldetails
- Edition: 1.0
- Umfang: 47 Seiten
- Sprache: Englisch
- Ausgabedatum: 2019-05
- Erscheinungsdatum: 2019-05-20