IEC TS 60079-39:2015
Norm
Explosive atmospheres - Part 39: Intrinsically safe systems with electronically controlled spark duration limitation
- Gültig
Alle Preise inkl. MwSt.
Bleiben Sie mit der IEC-Watchlist immer auf dem neuesten Stand
Mit der IEC-Watchlist haben Sie die Möglichkeit, die für Sie relevanten Normnummern oder technische Fachgebiete in Ihre persönliche Watchlist aufzunehmen. Bei Erscheinen einer neuen IEC-Norm erhalten Sie automatisch eine E-Mail.
Um eine Norm der IEC-Watchlist hinzufügen zu können, müssen Sie sich zuerst einloggen.
Zuständiges Komitee:
Hauptnummer/Reihe:
60079
IEC TS 60079-39:2015(E) specifies the construction, testing, installation and maintenance of Power-i apparatus and systems which utilise electronically controlled spark duration limitation to maintain an adequate level of intrinsic safety. This Technical Specification contains requirements for intrinsically safe apparatus and wiring intended for use in explosive atmospheres and for associated apparatus intended for connection to intrinsically safe circuits entering such atmospheres. This Technical Specification excludes the level of protection "ia" and the use of software-controlled circuits. This Technical Specification applies to electrical equipment utilising voltages not higher than 40 V d.c. and a safety factor 1,5 for Groups IIB, IIA, I and III. It is also applicable to Group IIC "ic" apparatus with a safety factor 1,0. Group IIC "ib" apparatus with a safety factor 1,5 are restricted to voltages up to 32 V d.c. This type of protection is applicable to electrical equipment in which the electrical circuits themselves are incapable of causing an explosion of the surrounding explosive atmospheres. This Technical Specification is applicable to intrinsically safe apparatus and systems which utilise electronically controlled spark duration limitation with the aim of providing more electrical power while maintaining an adequate level of safety. This Technical Specification is also applicable to electrical equipment or parts of electrical equipment located outside hazardous areas or protected by another type of protection listed in the IEC 60079 series, where the intrinsic safety of the electrical circuits in explosive atmospheres depends on the design and construction of such electrical equipment or parts of such electrical equipment. The electrical circuits located in the hazardous area are evaluated for use in such locations by applying this Technical Specification. This Technical Specification supplements and modifies the requirements of IEC 60079-0, IEC 60079-11, IEC 60079-14, IEC 60079-17 and IEC 60079-25. Keywords: Power-i apparatus, intrinsically safe apparatus and wiring intended for use in explosive atmospheres
The contents of the corrigendum of October 2020 have been included in this copy.
The contents of the corrigendum of October 2020 have been included in this copy.
Dieses Dokument wird folgenden, in Fettschrift gekennzeichneten, Fachgebiet(en) zugeordnet:
- 29Elektrotechnik
- 29.020Elektrotechnik im Allgemeinen
- 29.030Magnetische Werkstoffe
- 29.035Isolierstoffe
- 29.040Isolierende Fluide
- 29.045Halbleitende Stoffe
- 29.050Leitende Stoffe. Supraleitung
- 29.060Drähte. Kabel. Leitungen
- 29.080Isolierung
- 29.100Bauteile für elektrische Geräte
- 29.120Elektrisches Zubehör
- 29.130Schaltgeräte
- 29.140Lampen. Lampenzubehör
- 29.160Drehende elektrische Maschinen
- 29.180Transformatoren. Drosselspulen
- 29.200Gleichrichter. Stromrichter. Stabilisierte Stromversorgung
- 29.220Galvanische Zellen. Batterien
- 29.240Stromnetz
- 29.260Elektrische Betriebsmittel für den Einsatz unter besonderen Bedingungen
- 29.280Ortsfeste elektrische Bahnanlagen. Fahrstromversorgung
Artikeldetails
- Edition: 1.0
- Umfang: 51 Seiten
- Sprache: Englisch
- Ausgabedatum: 2015-06
- Erscheinungsdatum: 2015-06-11
Item 1 of 9
Item 1 of 5