IEC TS 63414:2025
Norm
Artificial pollution tests on high-voltage polymeric insulators to be used on AC and DC systems
- Gültig
Alle Preise inkl. MwSt.
Bleiben Sie mit der IEC-Watchlist immer auf dem neuesten Stand
Mit der IEC-Watchlist haben Sie die Möglichkeit, die für Sie relevanten Normnummern oder technische Fachgebiete in Ihre persönliche Watchlist aufzunehmen. Bei Erscheinen einer neuen IEC-Norm erhalten Sie automatisch eine E-Mail.
Um eine Norm der IEC-Watchlist hinzufügen zu können, müssen Sie sich zuerst einloggen.
Zuständiges Komitee:
Hauptnummer/Reihe:
63414
IEC TS 63414:2025 is applicable for the determination of the AC and DC pollution flashover and withstand voltage characteristics of insulators with polymeric housing, to be used outdoors in HV applications and exposed to polluted environments. This is also applicable for insulators with hydrophobic coatings. This document refers to AC systems with a rated voltage greater than 1 000 V and DC systems with a rated voltage greater than 1 500 V.
The object of this technical specification is to prescribe standardized test methods, requirements and procedures for artificial pollution tests applicable to polymeric insulators for overhead lines including traction lines, station post and hollow insulators of equipment. Available test experience with polymeric station post and hollow insulators, especially for DC applications, is limited.
The proposed tests are not applicable to ceramic and glass insulators without polymeric housing, to greased insulators or to special types of insulators (e.g., insulators with semiconducting glaze).
Differently to ceramic and glass insulators without polymeric housing:
- The pollution performance of insulators with polymeric housing varies with the hydrophobicity condition of the surface. The specific conditions simulated by standardized tests might not represent the actual dynamic field conditions.
- The determination of the flashover and/or withstand voltage under pollution conditions is not enough for dimensioning. Additional constraints related to possible ageing are also to be considered.
- If the Hydrophobicity Transfer Material (HTM) test according to IEC TR 62039 confirms that an insulator is non-HTM, it can be tested according to IEC 60507 or IEC TS 61245.
The object of this technical specification is to prescribe standardized test methods, requirements and procedures for artificial pollution tests applicable to polymeric insulators for overhead lines including traction lines, station post and hollow insulators of equipment. Available test experience with polymeric station post and hollow insulators, especially for DC applications, is limited.
The proposed tests are not applicable to ceramic and glass insulators without polymeric housing, to greased insulators or to special types of insulators (e.g., insulators with semiconducting glaze).
Differently to ceramic and glass insulators without polymeric housing:
- The pollution performance of insulators with polymeric housing varies with the hydrophobicity condition of the surface. The specific conditions simulated by standardized tests might not represent the actual dynamic field conditions.
- The determination of the flashover and/or withstand voltage under pollution conditions is not enough for dimensioning. Additional constraints related to possible ageing are also to be considered.
- If the Hydrophobicity Transfer Material (HTM) test according to IEC TR 62039 confirms that an insulator is non-HTM, it can be tested according to IEC 60507 or IEC TS 61245.
Dieses Dokument wird folgenden, in Fettschrift gekennzeichneten, Fachgebiet(en) zugeordnet:
- 29Elektrotechnik
- 29.020Elektrotechnik im Allgemeinen
- 29.030Magnetische Werkstoffe
- 29.035Isolierstoffe
- 29.040Isolierende Fluide
- 29.045Halbleitende Stoffe
- 29.050Leitende Stoffe. Supraleitung
- 29.060Drähte. Kabel. Leitungen
- 29.080Isolierung
- 29.100Bauteile für elektrische Geräte
- 29.120Elektrisches Zubehör
- 29.130Schaltgeräte
- 29.140Lampen. Lampenzubehör
- 29.160Drehende elektrische Maschinen
- 29.180Transformatoren. Drosselspulen
- 29.200Gleichrichter. Stromrichter. Stabilisierte Stromversorgung
- 29.220Galvanische Zellen. Batterien
- 29.240Stromnetz
- 29.260Elektrische Betriebsmittel für den Einsatz unter besonderen Bedingungen
- 29.280Ortsfeste elektrische Bahnanlagen. Fahrstromversorgung
Artikeldetails
- Edition: 1.0
- Umfang: 39 Seiten
- Sprache: Englisch
- Ausgabedatum: 2025-12
- Erscheinungsdatum: 2025-12-16
Item 1 of 9