Cover IEC 60684-3-165:2004
größer

IEC 60684-3-165:2004

Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheet 165: Extruded polyolefin, flame retarded, limited fire hazard sleeving

Circulation Date: 2004-05
Edition: 1.0
Language: EN-FR - bilingual english/french
Seitenzahl: 17 VDE Artno.: 211367

Content

Gives the requirements for two types of extruded polyolefin, flame retarded, limited fire hazard sleeving. Type A: Thin wall - Internal diameter up to 30 mm Type B: Thick wall - Internal diameter up to 30 mm These sleevings are normally supplied in the following colours: black, red, green, blue, white and yellow. These sleevings are for use up to temperatures of 90 °C. Sizes or colours other than those listed in this standard may be available as custom items. These items are considered to comply with this standard if they comply with the requirements listed in Tables 2, 3, and 4, excluding dimensions. Materials which conform to this specification meet established levels of performance. However, the selection of a material by a user for a specific application should be based on the actual requirements necessary for adequate performance in that application and not based on this specification alone.