Double Coil Permeameter for the Characterization of Magnetic Materials
Conference: GeMiC 2009 - German Microwave Conference
03/16/2009 - 03/18/2009 at München, Germany
Proceedings: GeMiC 2009
Pages: 3Language: englishTyp: PDF
Personal VDE Members are entitled to a 10% discount on this title
Authors:
Hettstedt, Falk; Knöchel, Reinhard (Institute of Electrical and Information Engineering, Faculty of Engineering, Christian-Albrechts-University, Kaiserstrasse 2, 24143 Kiel, Germany)
Schürmann, Ulrich; Quandt, Eckhard (Inorganic Functional Materials, Faculty of Engineering, Christian-Albrechts-University, Kaiserstrasse 2, 24143 Kiel, Germany)
Abstract:
This paper presents a permeameter for the measurement of the complex permeability of magnetic thin films up to several GHz. The permeameter consists of a driving coil and a pickup coil. The magnetic properties of the magnetic thin film sample inserted into the pickup coil cause the change of the coupling between the driving and pickup coil. Then, the complex permeability of the sample can be obtained from the coupling variation. The geometry is optimized with respect to sensitivity and self resonance by field simulations using HFSS. Small residual errors at low frequencies are removed through vibrating sample magnetometer measurements.