Investigation on Isolated Failure Mechanisms in Active Power Cycle Testing

Conference: PCIM Europe 2015 - International Exhibition and Conference for Power Electronics, Intelligent Motion, Renewable Energy and Energy Management
05/19/2015 - 05/20/2015 at Nürnberg, Deutschland

Proceedings: PCIM Europe 2015

Pages: 8Language: englishTyp: PDF

Personal VDE Members are entitled to a 10% discount on this title

Authors:
Junghaenel, M.; Strobel, J.; Scheuermann, U. (SEMIKRON Elektronik GmbH & Co. KG, Sigmundstr. 200, 90431 Nuremberg, Germany)
Schmidt, R. (Siemens AG, Frauenauracher Str. 80, 91056 Erlangen, Germany)

Abstract:
In the last decades, considerable effort has been invested to predict the operational lifetime of classical IGBT power modules. Most of these investigations were based on end-oflife active power cycling tests. Two dominant failure modes were hereby identified: solder fatigue and Al wire bond failure. However, the lifetime models derived from these accelerated tests could not discriminate between these failure modes. Recently, more reliable interconnection technologies were developed, and both failure modes can now be studied independently. The experimental results presented in this paper show that the failure modes cannot be described within one common lifetime model, as both the dependence on the temperature swing ??Tj and the influence of the absolute mean temperature Tjm differ significantly for both failures. As a consequence, the extrapolation of accelerated test results might lead to erroneous lifetime expectations.