VGE,th(T) and VCE(T)-method to measure the cooling of an IGBT after short circuit in an inverter

Conference: PCIM Europe 2019 - International Exhibition and Conference for Power Electronics, Intelligent Motion, Renewable Energy and Energy Management
05/07/2019 - 05/09/2019 at Nürnberg, Deutschland

Proceedings: PCIM Europe 2019

Pages: 7Language: englishTyp: PDF

Personal VDE Members are entitled to a 10% discount on this title

Authors:
Hiller, Sebastian (SEMIKRON Elektronik GmbH & Co. KG, Germany)
Zhang, Jianjie; Lutz, Josef (Chemnitz University of Technology, Germany)

Abstract:
In order to protect an inverter of a sudden failure due to aged semiconductors, it is necessary to monitor the state of health of those in the inverter application. To measure the state of health of the chip-solder, it is not necessary to heat up the whole device to the thermal equilibrium. It is sufficient to heat up the chip only, in this case. This can be done by driving a short circuit pulse with reduced gate voltage. By measuring the cooling behaviour and comparing it with the initial state it is possible to detect chip-solder degradation. Aiming to measure the cooling of IGBTs, two different methods are used, the VCE(T) and the VGE,th(T) method. These methods are presented in the following.