Standard:
NEW DIN EN IEC 61442 VDE 0278-442:2025-06Test methods for accessories for power cables with rated voltages from 6 kV (Um = 7,2 kV) up to 36 kV (Um = 42 kV)
|
|
Standard:
DIN VDE 0278-629-2 VDE 0278-629-2:2025-02Test requirements for accessories for use on power cables of rated voltage from 3,6/6(7,2) kV up to 20,8/36(42) kV Part 2: Cables with impregnated paper insulation; |
Standard:
DIN VDE 0278-629-3 VDE 0278-629-3:2025-02Test requirements for accessories for use on power cables of rated voltage from 3,6/6(7,2) kV up to 20,8/36(42) kV Part 3: Transition joints between cables with impregnated paper insulation and cables with extruded insulation; |
Draft:
E DIN IEC 60332-1-2 VDE 0482-332-1-2:2025-02Tests on electric and optical fibre cables under fire conditions Part 1-2: Test for vertical flame propagation for a single insulated wire or cable – Procedure for 1 kW pre-mixed flame |
Standard:
DIN EN IEC 60799 VDE 0626:2025-02Electrical accessories Cord sets and interconnection cord sets |
Standard:
DIN VDE 0276-620 VDE 0276-620:2024-12Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kV up to and including 20,8/36 (42) kV;
|
Standard:
DIN VDE 0276-2067 VDE 0276-2067:2024-12Power cables with extruded insulation and their accessories for rated voltages above 150 kV (Um = 170 kV) up to 500 kV (Um = 550 kV) Test methods and requirements |
|
Draft:
E DIN IEC 60331-4 VDE 0482-331-4:2024-11Tests for electric cables under fire conditions – Circuit integrity Part 4: Test method for fire with shock at a temperature of at least 830 °C for cables of rated voltage higher than 1 kV up to and including 30 kV |
Draft:
E DIN EN IEC 60851-3 VDE 0474-851-3:2024-07Winding wires – Test methods Part 3: Mechanical properties |
Draft:
E DIN EN IEC 60317-93 VDE 0474-317-93:2024-06Specifications for particular types of winding wires Part 93: Polyester or polyesterimide overcoated with polyamide-imide enamelled rectangular copper wire, class 220 |
Draft:
E DIN EN IEC 60317-89 VDE 0474-317-89:2024-05Specifications for particular types of winding wires Part 89: Polyesterimide enamelled round aluminum wire, class 200 |
Draft:
E DIN VDE V 0283-5 VDE V 0283-5:2024-01Cables for use on AC-applications in photovoltaic and solar systems
|
Draft:
E DIN VDE V 0283-618-1 VDE V 0283-618-1:2024-01Electric cables Electric cables for photovoltaic systems with improved water resistance |
Standard:
DIN EN 50399 VDE 0482-399:2023-12Common test methods for cables under fire conditions Heat release and smoke production measurement on cables during flame spread test – Test apparatus, procedures, results; |
Standard:
DIN EN 50576 VDE 0482-576:2023-12Electric cables Extended application of test results for reaction to fire; |
Standard:
DIN VDE 0298-4 VDE 0298-4 Berichtigung 1:2023-10Application of cables and cords in power installations Part 4: Recommended current-carrying capacity for sheathed and nonsheathed cables for fixed wirings in and around buildings and for flexible cables and cords; Corrigendum 1 |
|
Standard:
DIN EN 50525-1 VDE 0285-525-1:2023-09Electric cables – Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Part 1: General requirements; |