Draft:
E DIN VDE 0636-3 VDE 0636-3:2023-03Low-voltage fuses Part 3: Supplementary requirements for fuses for use by unskilled persons (fuses mainly for household or similar applications) – Examples of standardized systems of fuses A to F |
Draft:
E DIN VDE 0636-2/A2 VDE 0636-2/A2:2023-01Low-voltage fuses Part 2: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) – Examples of standardized systems of fuses A to K |
Standard:
DIN IEC/IEEE 60255-118-1 VDE 0435-3118-1:2022-12Measuring relays and protection equipment Part 118-1: Synchrophasor for power systems – Measurements |
Draft:
E DIN EN IEC 60669-2-4 VDE 0632-2-4:2022-12Switches for household and similar fixed electrical installations Part 2-4: Particular requirements – Isolating switches |
Standard:
DIN VDE 0641-13 VDE 0641-13:2022-12Electrical accessories – Circuit-breakers for overcurrent protection for household and similar installations Part 3: Circuit-breakers for DC operation |
Standard:
DIN VDE 0670-2-453 VDE 0670-2-453:2022-12High-voltage switchgear and controlgear Part 2-453: Alternating current disconnector and earthing switches – Earthing switch – Rated voltage greater than or equal to 245 kV (AC) – Terminal and mounting dimensions, layout |
Standard:
DIN CLC/TS 51643-32 VDE V 0675-5-32:2022-12Low-voltage surge protective devices Part 32: Surge protective devices connected to the DC side of photovoltaic installations – Selection and application principles; |
Standard:
DIN EN 61643-31 VDE 0675-6-31 Berichtigung 1:2022-12Low-voltage surge protective devices Part 31: Requirements and test methods for SPDs for photovoltaic installations |
Standard:
DIN EN 61386-1 VDE 0605-1 Berichtigung 1:2022-10Conduit systems for cable management Part 1: General requirements |
Standard:
DIN VDE 0664-50/A11 VDE 0664-50/A11:2022-10Residual current devices with or without overcurrent protection for socket-outlets for household and similar uses;
|
Standard:
DIN VDE 0664-50/A12 VDE 0664-50/A12:2022-10Residual current devices with or without overcurrent protection for socket-outlets for household and similar uses;
|
Draft:
E DIN VDE 0100-443/A3 VDE 0100-443/A3:2022-09Low-voltage electrical installations Part 4-44: Protection for safety – Protection against voltage disturbances and electromagnetic disturbances – Clause 443 |
Draft:
E DIN VDE 0100-520/A1 VDE 0100-520/A1:2022-09Low-voltage electrical installations Part 5-52: Selection and erection of electrical equipment – Wiring systems |
Draft:
E DIN VDE 0100-534/A2 VDE 0100-534/A2:2022-09Low-voltage electrical installations Part 5-53: Selection and erection of electrical equipment – Devices for protection for safety, isolation, switching, control and monitoring – Clause 534 |
Standard:
DIN EN IEC 60255-187-1 VDE 0435-3187-1:2022-09Measuring relays and protection equipment Part 187-1: Functional requirements for differential protection – Restrained and unrestrained differential protection of motors, generators and transformers |
Draft:
E DIN EN IEC 60127-8/A1 VDE 0820-8/A1:2022-09Miniature fuses Part 8: Fuse resistors with particular overcurrent protection |
Draft:
E DIN EN IEC 62275 VDE 0604-201:2022-08Cable management systems Cable ties for electrical installations |
Standard:
DIN EN IEC 61643-341 VDE 0845-5-41:2022-08Components for low-voltage surge protection Part 341: Performance requirements and test circuits for thyristor surge suppressors (TSS) |
Standard:
DIN EN 62752 VDE 0666-10:2022-07In-cable control and protection device for mode 2 charging of electric road vehicles (IC-CPD)
|
Standard:
DIN VDE 0100-420 VDE 0100-420:2022-06Low voltage electrical installations Part 4-42: Protection for safety – Protection against thermal effects |