This part of IEC 60034-27 provides guides for the measuring test procedures and the interpretation of test results for dielectric dissipation factor measurements on the stator winding insulation of rotating electrical machines. These guides are usually valid for rotating electrical machines operating at a rated voltage of 6 kV and higher.