Cover IEC 60156:2018
größer

IEC 60156:2018

Insulating liquids - Determination of the breakdown voltage at power frequency - Test method

Ausgabedatum: 2018-08
Edition: 3.0
Sprache: EN-FR - zweisprachig englisch/französisch
Seitenzahl: 37 VDE-Artnr.: 225856

Inhaltsverzeichnis

IEC 60156:2018 is now available as IEC 60156:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.

IEC 60156:2018 specifies the method for determining the dielectric breakdown voltage of insulating liquids at power frequency. The test procedure is performed in a specified apparatus, where the oil sample is subjected to an increasing AC electrical field until breakdown occurs. The method applies to all types of insulating liquids of nominal viscosity up to 350 mm2/s at 40 °C. It is appropriate both for acceptance testing on unused liquids at the time of their delivery and for establishing the condition of samples taken in monitoring and maintenance of equipment. This third edition cancels and replaces the second edition published in 1995. This edition constitutes a technical revision and, mainly, confirms the content of the previous edition even if some advances are included. The test method has not been changed for practical reason due to the very large number of instrumentation disseminated around the world, even if the use of stirring is now recommended.