Reliability Evolution of Au-Au, Au-Ru and Au-RuO2 Micro-Contacts

Konferenz: ICEC 2014 - The 27th International Conference on Electrical Contacts
22.06.2014 - 26.06.2014 in Dresden, Deutschland

Tagungsband: ICEC 2014

Seiten: 6Sprache: EnglischTyp: PDF

Persönliche VDE-Mitglieder erhalten auf diesen Artikel 10% Rabatt

Autoren:
Stilson, Christopher; Coutu, Ronald Jr. (Department of Electrical and Computer Engineering, Air Force Institute of Technology, Wright Patterson AFB, Ohio, 45433, USA)

Inhalt:
This paper presents a comparison between microcontact pairs of Au-Au, Au-Ru and Au-RuO2. The contact pairs were made with an evaporated Au lower planar contact and sputtered Au, Ru or RuO2 upper hemispherical contact. The RuO2 was reactively sputtered in both a 10% and 25% O2:Ar environment. The evolution of the contact area was observed by actuating the micro-contact to 1, 102, 103, 5 x 103, 104, 5 x 104, 105, 5 x 105, 106, 5 x 106 and 107 cycles. The micro-contacts were actuated using an external, calibrated point load. To examine the micro-contact performance, the contact resistance and force required to close the contact were monitored simultaneously throughout testing. At the above stated end point, the microcontact was folded back to evaluate the wear of the upper hemispherical and planar lower contact. The contacts were also examined with an scanning electron microscope to investigate the contact surfaces. This paper will present the contact evolution between contact pairs of Au-Au, Au-Ru and Au-RuO2 microcontacts between 1 and 107 cycles. It was found that the contact resistance for the Au/Ru was 1.7 Ω, Au/RuO2 10% was 1.36 Ω, Au/RuO2 25% was 0.036 Ω.