High Speed Electronic Over Current Breaker for DC-Grids without Additional Sensing

Konferenz: PCIM Europe 2016 - International Exhibition and Conference for Power Electronics, Intelligent Motion, Renewable Energy and Energy Management
10.05.2016 - 12.05.2016 in Nürnberg, Deutschland

Tagungsband: PCIM Europe 2016

Seiten: 8Sprache: EnglischTyp: PDF

Persönliche VDE-Mitglieder erhalten auf diesen Artikel 10% Rabatt

Autoren:
Wuerfel, Alexander; Adler, Johannes; Kaminski, Nando (University of Bremen, Germany)
Mauder, Anton (Infineon Technologies AG, Germany)

Inhalt:
An electronic over current breaker (OCB) for DC-grids without the need of additional sensing circuitry is presented. The OCB consists of standard Si-MOSFETs and is cascoded with SiC-JFETs for increased blocking capability. The over current detection threshold can be adjusted in a wide range. Due to the lack of additional sensing circuitry, the detection and clearing of a fault current is extremely fast and fail-safe compared to conventional OCBs at least with respect to the control.