Partial Discharge of Inductives in a High Frequency Application

Konferenz: PCIM Europe 2017 - International Exhibition and Conference for Power Electronics, Intelligent Motion, Renewable Energy and Energy Management
16.05.2017 - 18.05.2017 in Nürnberg, Deutschland

Tagungsband: PCIM Europe 2017

Seiten: 4Sprache: EnglischTyp: PDF

Persönliche VDE-Mitglieder erhalten auf diesen Artikel 10% Rabatt

Autoren:
Schmidhuber, Michael; Jungwirth, Herbert (SUMIDA Components & Modules GmbH, Germany)

Inhalt:
This paper presents an investigation on partial discharge in a transformer of a micro inverter. Due to the higher switching frequencies driven by wide bandgap (SiC and GaN) devices and also the demand for rising package densities, parasitics within the wire of certain components become more and more dominant. Also transients with a higher du/dt and/or di/dt lead to more voltage stress on the isolation. Thermal influences are not considered. Wire material datasheets do not provide essential information for those applications. The paper describes first measurement results on evaluating partial discharge whereas final design rules shall be derived from the full paper.